This version of the sensor has a built-in signal conditioner with a voltage or current output and a supply voltage of 5 / 24 V. The signal conditioner is fully integrated in the sensor body. Dimensions and parameters are identical to the EMS40 model. The output can be directly connected to a PLC or other measuring device with suitable inputs.

Supported Outputs
TypeSupply VoltageDirectionOutput
Voltage5 VDCTension / Compression0.5 .. 4.5 V
24 VDCTension / Compression2 .. 10 V
24 VDCTension and Compression2 .. 6 .. 10 V
Current24 VDCTension / Compression4 .. 20 mA
24 VDCTension and Compression4 .. 12 .. 20 mA
Weight0,07 kg
Dimensions38 × 38 × 22 cm
Load direction

Compression, Tension, Tension and Compression

Rated Capacity (Fn)

1KN, 2KN, 5KN, 10KN, 20KN, 50KN

Output

0,5 – 2,5 – 4,5 V (5 VDC), 0,5 – 4,5 V (5 VDC), 2 – 10 V (24 VDC), 2 – 6 – 10 V (24 VDC), 4 – 12 – 20 mA (24 VDC), 4 – 20 mA (24 VDC)

Datasheet EMS41 - SK Download.pdf
Datasheet EMS41 - EN Download.pdf
Model EMS40 / EMS41 - 1kN, 2kN, 5kN Download.stp
Model EMS40 / EMS41 - 10kN Download.stp
Model EMS40 / EMS41 - 20kN Download.stp
Model EMS40 / EMS41 - 50kN Download.stp
Rated capacity (F.S.)1 / 2 / 5 kN10 / 20 / 50 kN
Overload
- Safe
- Ultimate
- Permanent static load
- Dynamic load

130% Fn
150% Fn
75% Fn
50% Fn
Voltage output
- Standard
- With zero offset
- Customer design

2 .. 10 V
2 .. 6 .. 10 V
0.5 .. 10 V
Min. load impedance2 kΩ
Current output
- Standard
- With zero offset
- Custom design

4 .. 20 mA
4 .. 12 .. 20 mA
1 .. 20
Max. load impedance500 kΩ
Supply voltage
- Range
- Current consumption (max)

24 ± 10% VDC
40 mA
Max error
- Non-linearity
- Hysteresis
- Creep (30 min)

0.25% F.S.
0.25% F.S.
0.1% F.S.

0.5% F.S.
0.5% F.S.
0.1% F.S.
Temperature effect
- On Zero
- On Output

0.15% F.S./10°C
0.15% F.S./10°C
Product was successfully added to your cart!