This version of the sensor has a built-in signal conditioner with a voltage or current output and a supply voltage of 5 / 24 V. The signal conditioner is fully integrated in the sensor body. Dimensions and parameters are identical to the EMS110 model. The output can be directly connected to a PLC or other measuring device with suitable inputs.
Supported outputs | |||
---|---|---|---|
Type | Supply voltage | Direction | Output |
Voltage | 5 VDC | Tension / Compression | 0.5 .. 4.5 V |
24 VDC | Tension / Compression | 2 .. 10 V | |
24 VDC | Tension and Compression | 2 .. 6 .. 10 V | |
Current | 24 VDC | Tension / Compression | 4 .. 20 mA |
24 VDC | Tension and Compression | 4 .. 12 .. 20 mA |
Weight | 0,07 kg |
---|---|
Dimensions | 55 × 10 × 55 cm |
Load direction | Compression, Tension, Tension and Compression |
Rated Capacity (Fn) | 200N, 500N, 1KN, 2KN, 5KN, 10KN |
Output | 0,5 – 2,5 – 4,5 V (5 VDC), 0,5 – 4,5 V (5 VDC), 2 – 10 V (24 VDC), 2 – 6 – 10 V (24 VDC), 4 – 12 – 20 mA (24 VDC), 4 – 20 mA (24 VDC) |
Datasheet EMS111 - SK | Download | |
Datasheet EMS111 - EN | Download | |
Model EMS110 / EMS111 - 200N | Download | .stp |
Model EMS110 / EMS111 - 500N | Download | .stp |
Model EMS110 / EMS111 - 1kN | Download | .stp |
Model EMS110 / EMS111 - 2kN | Download | .stp |
Model EMS110 / EMS111 - 5kN | Download | .stp |
Model EMS110 / EMS111 - 10kN | Download | .stp |
Rated capacity (F.S.) | 200 / 500 N | 1 / 2 / 5 / 10 kN |
Overload - Safe - Ultimate - Permanent static load - Dynamic load |
120% F.S. 150% F.S. 75% F.S. 50% F.S. |
|
Max error - Non-linearity - Hysteresis - Creep (30 min) |
0.1% F.S. 0.1% F.S. 0.05% F.S. |
|
Temperature effect - On zero - On output |
0.15% F.S./10°C 0.15% F.S./10°C |
|
Temperature range - Nominal - Operating |
0°C .. +50°C -10°C .. +50°C |
|
Protection | IP54 | |
Body material | Aluminium | Stainless steel |
Cable - Type / Length |
LifYDY 7 x 0.05 / 2m |
LifYDY 7 x 0.1 / 2m |