In-Line robust load cell with very good metrological characteristics suitable for measurements in demanding conditions like tanks weighting.

Weight 0,22 kg
Dimensions 95 × 45 × 45 cm
Load direction

Compression, Tension, Tension and Compression

Rated Capacity (Fn)

500N, 1KN, 2KN, 5KN, 10KN, 20KN, 50KN

Datasheet EMS150 - SK Download .pdf
Datasheet EMS150 - EN Download .pdf
Model EMS150 / EMS151 - 500N Download .stp
Model EMS150 / EMS151 - 1kN Download .stp
Model EMS150 / EMS151 - 2kN Download .stp
Model EMS150 / EMS151 - 5kN Download .stp
Model EMS150 / EMS151 - 10kN Download .stp
Model EMS150 / EMS151 - 20kN Download .stp
Model EMS150 / EMS151 - 50kN Download .stp
Model EMS150 / EMS151 - 100kN Download .stp
Model EMS150 / EMS151 - 200kN Download .stp
Rated capacities (F.S.) 0.5 / 1 / 2 / 5 / 10 / 20 / 50 / 100 / 200 kN
Overload
- Safe
- Ultimate
- Permanent static load
- Dynamic load

130% F.S.
200% F.S.
75% F.S.
50% F.S.
Nominal sensitivity (Cn) ± 2% 2.0 ± 0.04 mV/V
Zero balance ± 0.04 mV/V
Max. error
- Non-linearity
- Hysteresis

0.15% F.S.
0.15% F.S.
Temperature effect
- On zero
- On output

0.05% F.S./10°C
0.05% F.S./10°C
Bridge resistance
- Input
- Output

375 ± 20 Ω
350 ± 10 Ω
Insulation impedance > 500 MΩ
Excitation
- Recommended
- Maximal

7 .. 10 V
15 V
Temperature range
- Compensated
- Operating

0°C .. +50°C
-10°C .. +70°C
Protection IP54
Connection
- Cable version
- Type / Length

- Conector version
- Type


LifYDY 4 x 0.14 / 2 m


M12, 4 pin
Product was successfully added to your cart!